Opti LogoOPTI® CCA-TS2 Blood Gas and Electrolyte Analyzer

Our next generation of blood gas analyzers

The OPTI® CCA-TS2 Blood Gas and Electrolyte Analyzer:
  • Provides fast accurate results for blood gases, acid-base balance, electrolytes, ionized calcium, glucose, BUN and lactate.
  • Runs samples of whole blood, plasma and serum on single-use disposable cassettes.
  • Uses innovative optical technology.
  • Requires minimal maintenance.

cca-ts2Innovative, economical and comprehensive
Innovative optical technology
The OPTI® CCA-TS2 Blood Gas and Electrolyte Analyzer uses OPTI Medical’s optical fluorescence technology. This unique, patented technology does not use electrodes or contact points,  which eliminates the need for costly electrode maintenance.

Significant cost savings
The OPTI CCA-TS2 analyzer provides lab-quality results with zero standby cost. The single-use consumable is only used during a measurement and safely locks waste inside.

Wide operating temperature
The OPTI CCA-TS2 analyzer has a measuring chamber heated to 37°C (98.6°F). This allows for a wide operating temperature range to meet the needs of colder environments, such as the operating room.

Comprehensive test menu
To help meet exact testing needs, the OPTI CCA-TS2 analyzer has a variety of cassette configurations available. Each cassette comes individually wrapped, in cartons of 25, reducing the potential for consumable waste.

Technology—Principles of operation

The OPTI® CCA-TS2 Blood Gas and Electrolyte Analyzer is a microprocessor-based instrument that measures optical fluorescence from discreet sensors called optical electrodes (optodes). A disposable, single-use cassette contains all of the elements needed for calibration, sample measurement and waste containment. Specific calibration information from the cassette is read into the analyzer by swiping the cassette package through the bar-code reader. The cassette is then placed into the measurement chamber.
The analyzer warms the cassette to 37.0°C (±0.1°C)/98.6°F (±0.1°F), and it performs a calibration verification on the sensors for PCO2 and PO2 by passing a precision calibration gas mixture across the optode sensors. The pH and electrolyte channels are calibrated with precision buffer solution contained in the cassette. When calibration is verified, the analyzer aspirates the blood sample into the cassette and across the optode sensors. After equilibrating with the blood sample, fluorescence emission is then measured.

The OPTI CCA-TS2 single-use patient cassette includes these features:
  • Calibration of cassette before sampling—eliminates losing sample if cassette calibration fails
  • Long cassette shelf life—6–12 months from the date of manufacture
  • Easy and safe maintenance
  • Safe disposal—waste is locked in the cassette
  • Maintenance-free operation—no electrodes
  • Zero standby cost—no reagents required

OPTI® CCA-TS2 analyzer specifications

Calibration/Measurement

Sample Volume 125 µL (60µL for B60 cassette)
Calibration Time <90 seconds
Measurement Time <120 seconds
Typical Cycle Time <210 seconds
Operating Temperature 10–30°C (50–86°F)
Sample Type Whole blood, serum or plasma
Measurement Principle Optical fluorescence, reflectance
Sample Application Syringe, capillary or ComfortSampler®
Data Storage

·         500 patient records
·         70 QC samples per level
·         105 SRC samples per level
·         300 user IDs and passwords



Security

Password

Multiple levels of security with user-definable permissions

QC Lockout

User-definable QC lockout functions




Dimensions/Weight

Height x Width x Depth

124 x 362 x 230 mm (4.7 x 14.2 x 9.1 in)

Weight

4.3 kg (9.6 lb) with rechargeable battery pack




Miscellaneous

Voltage/Frequency

120 or 240 AC, 50–60 Hz

Power Consumption (max.)

110 VA

Interface

ASTM, ASCII, POCT protocols via USB or Ethernet

Approvals

CE, UL and IVDD